Ohmalloy Material Co.,Ltd

QUALITY BEST, INTEGRITY FIRST. www.ohmalloy.com

Manufacturer from China
Verified Supplier
10 Years
Home / Products / Thermocouple Cable /

Vitreous Silica High Temperature Thermocouple Cables ASTM Standard AWG 15 KCA Type

Contact Now
Ohmalloy Material Co.,Ltd
Visit Website
City:shanghai
Province/State:shanghai
Country/Region:china
Contact Person:MrQiu
Contact Now

Vitreous Silica High Temperature Thermocouple Cables ASTM Standard AWG 15 KCA Type

Ask Latest Price
Video Channel
Brand Name :OHMALLOY
Model Number :K-HP-HP-30
Certification :ISO9001-2008
Place of Origin :China(Shanghai)
MOQ :100meters
Price :negotiable
Payment Terms :T/T, L/C,
Supply Ability :500000meters per month
Delivery Time :10-15 days
Packaging Details :100m/spool, 305m/spool, 1000ft/spool, 1000m/spool
Material :Chromel, Copel
Insulation :Fiberglass, Vitreous Silica
Diameter :15 AWG
Color :ANSI code, IEC code, GB/T standard
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Type KCA Thermocouple Cable Chromel / Copel Material Viterous Silica Insulation

Specifications


1.Style:High temperature Wire
2.Thermocouple wire
Thermocouple wire Classification
Thermocouple level (high temperature level). This type of thermocouple wire is mainly suitable for thermocouple type K, J, E, T, N and L and other high temperature detection instrument, temperature sensor, etc.


Thermocouple variety and index


Thermocouple Variety and Index

Variety

Type

Measurement Range(°C)

NiCr-NiSi

K

-200-1300

NiCr-CuNi

E

-200-900

Fe-CuNi

J

-40-750

Cu-CuNi

T

-200-350

NiCrSi-NiSi

N

-200-1300

NiCr-AuFe0.07

NiCr-AuFe0.07

-270-0

3 . Dimensions and Tolerance of Fiberglass Insulated Thermocouple Wire

Dimensions / Tolerance mm ) : 4.0+-0.25


Color code & initial calibration tolerances for thermocouple wire:

Thermocouple Type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
Iron(+) vs.
Constantan(-)
J White/Red Brown 0°C to +285°C
285°C to +750°C
±2.2°C
± .75%
±1.1°C
± .4%
CHROMEL(+) vs.
ALUMEL(-)
K Yellow/Red Brown -200°C to -110°C
-110°C to 0°C
0°C to +285°C
285°C to +1250°C
± 2%
±2.2°C
±2.2°C
± .75%
±1.1°C
± .4%
Copper(+) vs.
Constantan(-)
T Blue/Red Brown -200°C to -65°C
-65°C to +130°C
130°C to +350°C
± 1.5%
±1°C
± .75%
± .8%
± .5°C
± .4%
CHROMEL(+) vs.
Constantan(-)
E Purple/Red Brown -200°C to -170°C
-170°C to +250°C
250°C to +340°C
340°C+900°C
± 1%
±1.7°C
±1.7°C
± .5%
±1°C
±1°C
± .4%
± .4%


Color Code & Initial Calibration Tolerance for Extension Wire:

Extension type ANSI Color Code Initial Calibration Tolerances
Wire Alloys Calibration +/-
Conductor
Jacket Temperature Range Standard
Limits
Special
Limits
Iron (+) vs. Constantan(-) JX White/Red Black 0°C to +200°C ±2.2°C ±1.1°C
CHROMEL (+) vs. ALUMEL (-) KX Yellow/Red Yellow 0°C to +200°C ±2.2°C ±1.1°C
Copper(+) vs. Constantan(-) TX Blue/Red Blue -60°C to +100°C ±1.1°C ± .5°C
CHROMEL(+) vs. Constantan(-) EX Purple/Red Purple 0°C to +200°C ±1.7°C ±1.1°C


Inquiry Cart 0